I can’t even figure out how to tell if it’s supported or not. If it is supported, I can’t figure out how to enable it. If it is enabled, idk where I should be seeing it in proxmox!

Can anyone point me in the right direction?

  • AlphaAutist@lemmy.world
    link
    fedilink
    English
    arrow-up
    4
    ·
    8 months ago

    It looks like it should be possible as both your cpu and motherboard support Intel VT-d

    https://ark.intel.com/content/www/us/en/ark/products/236781/intel-core-i7-processor-14700-33m-cache-up-to-5-40-ghz.html

    https://download.asrock.com/Manual/Z690 Extreme.pdf

    PCIe pass through isn’t enabled by default in Proxmox and requires some manual changes to the bootloader (grub or systemd-boot) as well as loading some kernel modules. You may also need to enable VT-d in your BIOS. You can read proxmox’ guide for enabling PCIe pass through here:

    https://pve.proxmox.com/wiki/PCI(e)_Passthrough

      • nemanin@lemmy.worldOP
        link
        fedilink
        English
        arrow-up
        1
        ·
        8 months ago

        Ok. So they are different?

        How do I tell which motherboards support IOMMU?

        I can’t find it as a filter or search option on any websites…?

              • nemanin@lemmy.worldOP
                link
                fedilink
                English
                arrow-up
                1
                ·
                6 months ago

                sorry this took so long… you know, life. trying that command altogether, I get this response: -bash: acpidump: command not found

                trying just egrep “DMAR|IVRS” (in case they are two commands) seems to hang the terminal session.

                I tried following a guide to enable PICe passthrough and get this. One important thing, there is no discrete GPU at the moment, I’m trying to pass through an HBA…

                root@prox:~# dmesg | grep -e IOMMU [ 0.100411] DMAR: IOMMU enabled [ 0.254862] DMAR-IR: IOAPIC id 2 under DRHD base 0xfed91000 IOMMU 1 [ 0.629143] pci 0000:00:02.0: DMAR: Skip IOMMU disabling for graphics [ 0.713978] DMAR: IOMMU feature fl1gp_support inconsistent [ 0.713979] DMAR: IOMMU feature pgsel_inv inconsistent [ 0.713980] DMAR: IOMMU feature nwfs inconsistent [ 0.713981] DMAR: IOMMU feature dit inconsistent [ 0.713982] DMAR: IOMMU feature sc_support inconsistent [ 0.713983] DMAR: IOMMU feature dev_iotlb_support inconsistent

              • nemanin@lemmy.worldOP
                link
                fedilink
                English
                arrow-up
                1
                ·
                6 months ago

                This may also help, my HBA is there:

                root@prox:~# for d in /sys/kernel/iommu_groups//devices/; do n=${d#/iommu_groups/}; n=${n%%/}; printf 'IOMMU group %s ’ “$n”; lspci -nns "${d##/}"; done IOMMU group 0 00:02.0 VGA compatible controller [0300]: Intel Corporation Raptor Lake-S GT1 [UHD Graphics 770] [8086:a780] (rev 04)

                IOMMU group 10 00:1f.0 ISA bridge [0601]: Intel Corporation Z690 Chipset LPC/eSPI Controller [8086:7a84] (rev 11)

                IOMMU group 10 00:1f.3 Audio device [0403]: Intel Corporation Alder Lake-S HD Audio Controller [8086:7ad0] (rev 11)

                IOMMU group 10 00:1f.4 SMBus [0c05]: Intel Corporation Alder Lake-S PCH SMBus Controller [8086:7aa3] (rev 11)

                IOMMU group 10 00:1f.5 Serial bus controller [0c80]: Intel Corporation Alder Lake-S PCH SPI Controller [8086:7aa4] (rev 11)

                IOMMU group 10 00:1f.6 Ethernet controller [0200]: Intel Corporation Ethernet Connection (17) I219-V [8086:1a1d] (rev 11)

                IOMMU group 11 01:00.0 Non-Volatile memory controller [0108]: Sandisk Corp Western Digital WD Black SN850X NVMe SSD [15b7:5030] (rev 01)

                IOMMU group 12 02:00.0 Ethernet controller [0200]: Realtek Semiconductor Co., Ltd. RTL8125 2.5GbE Controller [10ec:8125] (rev 05)

                IOMMU group 13 03:00.0 Non-Volatile memory controller [0108]: Micron/Crucial Technology Device [c0a9:5415] (rev 01)

                IOMMU group 14 04:00.0 PCI bridge [0604]: PLX Technology, Inc. PEX 8724 24-Lane, 6-Port PCI Express Gen 3 (8 GT/s) Switch, 19 x 19mm FCBGA [10b5:8724] (rev ca)

                IOMMU group 15 05:00.0 PCI bridge [0604]: PLX Technology, Inc. PEX 8724 24-Lane, 6-Port PCI Express Gen 3 (8 GT/s) Switch, 19 x 19mm FCBGA [10b5:8724] (rev ca)

                IOMMU group 16 05:08.0 PCI bridge [0604]: PLX Technology, Inc. PEX 8724 24-Lane, 6-Port PCI Express Gen 3 (8 GT/s) Switch, 19 x 19mm FCBGA [10b5:8724] (rev ca)

                IOMMU group 17 05:09.0 PCI bridge [0604]: PLX Technology, Inc. PEX 8724 24-Lane, 6-Port PCI Express Gen 3 (8 GT/s) Switch, 19 x 19mm FCBGA [10b5:8724] (rev ca)

                **IOMMU group 18 06:00.0 Serial Attached SCSI controller [0107]: Broadcom / LSI SAS3008 PCI-Express Fusion-MPT SAS-3 [1000:0097] (rev 02)

                IOMMU group 19 08:00.0 Serial Attached SCSI controller [0107]: Broadcom / LSI SAS3008 PCI-Express Fusion-MPT SAS-3 [1000:0097] (rev 02)**

                IOMMU group 1 00:00.0 Host bridge [0600]: Intel Corporation Device [8086:a740] (rev 01)

                IOMMU group 2 00:14.0 USB controller [0c03]: Intel Corporation Alder Lake-S PCH USB 3.2 Gen 2x2 XHCI Controller [8086:7ae0] (rev 11)

                IOMMU group 2 00:14.2 RAM memory [0500]: Intel Corporation Alder Lake-S PCH Shared SRAM [8086:7aa7] (rev 11)

                IOMMU group 3 00:15.0 Serial bus controller [0c80]: Intel Corporation Alder Lake-S PCH Serial IO I2C Controller #0 [8086:7acc] (rev 11)

                IOMMU group 4 00:16.0 Communication controller [0780]: Intel Corporation Alder Lake-S PCH HECI Controller #1 [8086:7ae8] (rev 11)

                IOMMU group 5 00:17.0 SATA controller [0106]: Intel Corporation Alder Lake-S PCH SATA Controller [AHCI Mode] [8086:7ae2] (rev 11)

                IOMMU group 6 00:1a.0 PCI bridge [0604]: Intel Corporation Alder Lake-S PCH PCI Express Root Port #25 [8086:7ac8] (rev 11)

                IOMMU group 7 00:1c.0 PCI bridge [0604]: Intel Corporation Alder Lake-S PCH PCI Express Root Port #2 [8086:7ab9] (rev 11)

                IOMMU group 8 00:1c.4 PCI bridge [0604]: Intel Corporation Alder Lake-S PCH PCI Express Root Port #5 [8086:7abc] (rev 11)

                IOMMU group 9 00:1d.0 PCI bridge [0604]: Intel Corporation Alder Lake-S PCH PCI Express Root Port #9 [8086:7ab0] (rev 11)

                • wildbus8979@sh.itjust.works
                  link
                  fedilink
                  English
                  arrow-up
                  2
                  ·
                  edit-2
                  6 months ago

                  You should be good to go. Make sure vfio is loaded in the modules-load.d

                  vfio
                  vfio_iommu_type1
                  vfio_pci
                  vfio_virqfd
                  

                  Make sure the module options are set correctly and the kernel module is blacklisted in /etc/modprobe.d/vfio.conf

                  options vfio-pci ids=1000:0097
                  blacklist MODULE_NAME
                  

                  Make sure.IOMMU is enabled in your kernel command line (ex via grub): intel_iommu=on iommu=pt

                  This is probably not complete, but it should get you pretty far into allowing you to add the pci device in the hardware config of your vm

        • Possibly linux@lemmy.zip
          link
          fedilink
          English
          arrow-up
          1
          arrow-down
          1
          ·
          8 months ago

          Its your CPU and yes it does support it as all Intel CPUs made within the last few years have support.

  • Decronym@lemmy.decronym.xyzB
    link
    fedilink
    English
    arrow-up
    1
    ·
    edit-2
    6 months ago

    Acronyms, initialisms, abbreviations, contractions, and other phrases which expand to something larger, that I’ve seen in this thread:

    Fewer Letters More Letters
    NAS Network-Attached Storage
    NVMe Non-Volatile Memory Express interface for mass storage
    PCIe Peripheral Component Interconnect Express
    SATA Serial AT Attachment interface for mass storage
    SSD Solid State Drive mass storage

    5 acronyms in this thread; the most compressed thread commented on today has 10 acronyms.

    [Thread #739 for this sub, first seen 6th May 2024, 05:15] [FAQ] [Full list] [Contact] [Source code]

  • Possibly linux@lemmy.zip
    link
    fedilink
    English
    arrow-up
    1
    ·
    8 months ago

    Start by going into your firmware setting (hold del on boot) and enabling virtualization and all extensions.

    Once that’s done you can just click on add hardware and then ePCI device. If its a GPU it will require more setup.

    • roofuskit@lemmy.world
      link
      fedilink
      English
      arrow-up
      1
      ·
      8 months ago

      No, bifurcation is s splitting the lanes in the actual l actual slot between devices. Usually for something like an m.2 adapter board.

    • nemanin@lemmy.worldOP
      link
      fedilink
      English
      arrow-up
      1
      ·
      8 months ago

      Well, that’s at least part of my problem. I have no idea what it would be called so it’s hard to google. I guess the underlying technology is all ‘IOMMU’, but each motherboard manufacture and Intel and AMD all have other names for it…

      I’m trying to pass an HBA through to a VM for a NAS.